3
VELUX 41
Integration – more windows
Additional elements below roof window
ADDITIONAL ELEMENT GIL ABOVE
VERTIVAL WINDOW ELEMENT VFE
Vertical window element VFE can be installed below a combination
of a roof window with addtional window element GIL.
For this purpose, use flashings EFW/EFL together with flashing
extensions ETW/ETL.
As the sash of additional element GIL cannot be opened, it is neces-
sary to remove it in order to fit covers between GIL and the vertical
window element.
Follow these guidelines during installation:
1. As the sash of the additional element GIL is secured with screws,
the screws must be loosened. Depending on the roof pitch, it may
be necessary to remove the sash.
2. Fit covers between the additional element and the vertical
window element.
3. Having fitted the covers, refit sash.